1. Efficiency on Particle-Sizes from 0.453 - 0.017 Micron.
Made by V.I.T.O. - contract 2000/MIM/R/7 - test nr. 991351
| Particle size in Micron | Input Particles per cm³ | MedicCleanAir Efficiency in % |
| 0.017 | 37.561 | 99.27 |
| 0.019 | 40.175 | 99.37 |
| 0.029 | 68.550 | 99.60 |
| 0.093 | 124.092 | 100.00 |
| 0.107 | 135.580 | 100.00 |
| 0.255 | 76.180 | 100.00 |
| 0.340 | 24.427 | 100.00 |
| 0.392 | 12.040 | 100.00 |
| 0.453 | 4.791 | 100.00 |
note: 1 micron = 0.001mm
2. Efficiency on all Particle Sizes ranging from 0.453 Micron to 0.017 Micron
Made by V.I.T.O. - contract 2000/MIM/R/7 - test nr. 991351
Note: these figures on efficiency are on particles down
to 0.017 microns.
For airborne infections such as measles, aspergillus spp, tuberculosis,
SARS, varicella, MRSA particles, (Avian) Influenza, etc, the efficiency
of MedicCleanAir® units is 100 %.
The Hepa 14 or ULPA 15 class filtration have a 100 % captation
on the sizes of these species.
| Test | MedicCleanAir Efficiency in % |
| no. 1 | 99.98 |
| no. 2 | 99.97 |
| no. 3 | 99.92 |
| no. 4 | 99.98 |
| no. 5 | 99.97 |
| no. 6 | 99.92 |
| no. 7 | 100.00 |
| no. 8 | 99.97 |
| no. 9 | 100.00 |
| no. 10 | 100.00 |
| no. 11 | 99.97 |
| no. 12 | 99.96 |
| no. 13 | 99.97 |
| no. 14 | 100.00 |
| no. 15 | 99.94 |
| no. 16 | 100.00 |
| no. 17 | 100.00 |
| no. 18 | 99.97 |
| no. 19 | 100.00 |
| no. 20 | 100.00 |
3. Efficiency on representative selection of Indoor Gases and Chemical compounds.
Made by V.I.T.O. - contract 2000/MIM/R/7 - test nr. 991351
| Product | Max. Indoor Values µm³ | Offered Values µm³ | MedicCleanAir Efficiency in % |
| Ozone | 400 | 400 | 99 |
| Nitrogen Dioxide | 500 | 800 | 99 |
| Heptane | 556 | 530 | 96 |
| Hexane | 338 | 325 | 91 |
| Nonanal | 407 | 400 | 97 |
| Cyclohexane | 335 | 340 | 90 |
| Methylcyclohexane | 504 | 490 | 96 |
| Trichlorethene | 106 | 175 | 89 |
| Tetrachlorethene | 205 | 200 | 95 |
| Benzene | 148 | 145 | 95 |
| Toluene | 2.252 | 2.100 | 97 |
| Ethylbenzene | 138 | 135 | 96 |
| Dichlorbenzene | 299 | 291 | 97 |
| Glutaraldehyde | not known | 120 | 98 |
4. Special tests for MedicCleanAir Heavy Duty Filter Cartridge in relation to the products used in IC Burn Units and O.T. (Anaesthetics) and products used in the preparation of Cytostatic Products for Oncology (Pharmacy Department)
Produkte Pharma Bereich / Apotheke
Analyse - Testdaten / Produkte / MCA Aktivkohle
| Substanz: | überwiegend Organisch< |
| Molekular Struktur: | Molekulargewicht hoch bis sehr hoch |
| Produkte | Formula |
| Mitolactol | C6 - H12 - Br2 - O4 |
| Mitomycin | C15 - H18 - N4 - O5 |
| Mitopodozide | C24 - H30 - N2 - O8 |
| Mitotane | C14 - H10 - Cl4 |
| Mitoxantrone | C22 - H28 - N4 - O6 |
| Mitobronitol | C6 - H12 - Br2 - C4 |
| Mephalan | C13 - H18 - Cl2 - N2 - O2 |
| Mechlorethamine Oxide | C5 - H11 - Cl2 - N - O |
| Plicamycin | C52 - H76 - O24 |
| Thiotepa | C6 - H12 - N3 - P - S |
| 'fludarabine phosphate' | |
| Estramustine | C23 - H31 - Cl2 - N - O3 |
| Epirubicin | C27 - H29 - N - O11 |
| Methotrexate | C20 - H22 - N8 - O5 |
| Fluorouracil | C4 - H3 - F - N2 - O2 |
| Ifosfamide | C7 - H15 - Cl2 - N2 - O2 - P |
| Streptozocin | C8 - H15 - N3 - O7 |
| Etoposide | C29 - H32 - O13 |
| Teniposide | C32 - H32 - O13 - S |
| Vincristine | C46 - H56 - N4 - O10 |
| Vindesine | C43 - H55 - N5 - O7 |
| Vinblastine | C46 - H58 - N4 - O9 |
| Daunoribicin | C27 - H29 - N - O10 |
| Ganciclovir | C9 - H13 - N5 - O4 |
| Cisplatin | Cl2 - H6 - N2 - Pt |
| Chlormethine | C5 - H11 - Cl2 - N |
| Carmustine | C5 - H9 - Cl2 - N3 - O2 |
| Carboplatin | C6 - H12 - N2 - O4 - Pt |
| Azathioprine | C9 - H7 - N7 - O2 - S |
| Amsacrine | C21 - H19 - N3 - O3 - S |
| Cytarabine | C9 - H13 - N3 - O5 |
| Dacarbazine | C6 - H10 - N6 - O |
| Doxorubicin | C27 - H29 - N - O11 |
| Cyclophosphamide | C7 - H15 - Cl2 - N2 - O2 - P |
Results:
Adsorption capacity of the Heavy Duty Filter Cartridge: Nahezu Ideal, Minimum 90%. Explanation: the activated carbon used in the MedicCleanAir - Heavy Duty Filter Cartridge is of the type 'non-impregnated'. The molecular structures of the above mentioned products is high to very high which makes them ideal for adsorption by the MedicCleanAir - Heavy Duty Filter Cartridge.